Koncept Four Pole ELCB

Koncept Four Pole ELCB/RCCB 40A To 63A

Product details

Brand Koncept
Product Code KMFP RCCB
Iteam Name Earth Leakage Circuit Breaker. Residual Current Circuit Breaker.
Iteam Name Shat ELCB/RCCB
Descripttion Modal Four Pole
Rating In Amp 40-Ams, 63-Ams
Breaking Capacity 10 KA
Mark ISI Mark
Series C
Rated Voltage 240/415V
Frequency 50 Hz
Senstvity 30Am
Item Dimensions LxWxH 7cm x 8.4 x 7
Cage Size 35 sq. mm.
Marc ISI is12640-1

Product description

RCCB/ELCB must be installed on standard 35 mm DIN rail channelIngress Protection
RCCB / ELCB has finger-proof IP 20 terminals. It is advisable to mount
RCCB / ELCB inside panel/distribution boards having degree of
protection more than 1P 30 to 1P 65 depending on surrounding conditions.
Higher degree of protection can be achieved with Distribution Boards.

HAZARD OF IMPROPER OPERATION
Protect, as per IEC 61 008, each RCCB/ELCB by suitable over current protection device i.e. fuse or MCB
Failure to follow these instructions will result in serious injury or equipment damage.
CONNECTION

NORMAL TEST

    RCCB / ELCB must be in ON position and the power supply be switched ON.
1. To test the operation of the RCCB / ELCB after installation, Press the test button on the front of the device.
The RCCB / ELCB should trip every time: failure to do so indicates either no supply to the RCCB / ELCB or a faulty device.

2. A test for the effectiveness of the RCCB / ELCB in the protected installation should be carried out monthly

HAZARD OF IMPROPER OPERATION

Do not use Test Button to switch OFF RCCB/ELCB:

Failure to follow these instructions will result in serious injury or equipment damage.
TEST CERTIFICATE
We he Gecia es that our product
Description:  Residual Current Circuit Breaker (RCCB)
                     Earth Leakage Circuit Breaker (ELCB)
are tested at our factory as per routine tests stated in
IS 12640-1: 2008
IS 12640-1
IEC61008-1: 1996

Tests                                              Result
Tripping test                                     Ok
Trip Current                                      Ok
Tripping Time                                   Ok
Electric Strengh Test at 1500V.         Pass
Performance of the test device         Pass

This product is currently out of stock and unavailable.

SKU: 0391 Categories: ,

Koncept Four Pole ELCB/RCCB 40A To 63A

Product details

Brand Koncept
Product Code KMFP RCCB
Iteam Name Earth Leakage Circuit Breaker. Residual Current Circuit Breaker.
Iteam Name Shat ELCB/RCCB
Descripttion Modal Four Pole
Rating In Amp 40-Ams, 63-Ams
Breaking Capacity 10 KA
Mark ISI Mark
Series C
Rated Voltage 240/415V
Frequency 50 Hz
Senstvity 30Am
Item Dimensions LxWxH 7cm x 8.4 x 7
Cage Size 35 sq. mm.
Marc ISI is12640-1

Product description

RCCB/ELCB must be installed on standard 35 mm DIN rail channelIngress Protection
RCCB / ELCB has finger-proof IP 20 terminals. It is advisable to mount
RCCB / ELCB inside panel/distribution boards having degree of
protection more than 1P 30 to 1P 65 depending on surrounding conditions.
Higher degree of protection can be achieved with Distribution Boards.

HAZARD OF IMPROPER OPERATION
Protect, as per IEC 61 008, each RCCB/ELCB by suitable over current protection device i.e. fuse or MCB
Failure to follow these instructions will result in serious injury or equipment damage.
CONNECTION

NORMAL TEST

    RCCB / ELCB must be in ON position and the power supply be switched ON.
1. To test the operation of the RCCB / ELCB after installation, Press the test button on the front of the device.
The RCCB / ELCB should trip every time: failure to do so indicates either no supply to the RCCB / ELCB or a faulty device.

2. A test for the effectiveness of the RCCB / ELCB in the protected installation should be carried out monthly

HAZARD OF IMPROPER OPERATION

Do not use Test Button to switch OFF RCCB/ELCB:

Failure to follow these instructions will result in serious injury or equipment damage.
TEST CERTIFICATE
We he Gecia es that our product
Description:  Residual Current Circuit Breaker (RCCB)
                     Earth Leakage Circuit Breaker (ELCB)
are tested at our factory as per routine tests stated in
IS 12640-1: 2008
IS 12640-1
IEC61008-1: 1996

Tests                                              Result
Tripping test                                     Ok
Trip Current                                      Ok
Tripping Time                                   Ok
Electric Strengh Test at 1500V.         Pass
Performance of the test device         Pass

4 Pol

40 Amp, 63 Amp